AZ2000DSZ: Totaliser with DSZ dosing electronics
The AZ2000DSZ measures the electric charge passed through an electroplating process. A six-digit electromechanical totaliser displays the accumulated value and can be reset with a key.
Dosing based on electric charge
The integrated DSZ uses a potential-free relay contact (230 V / 10 A) to run a connected dosing pump or solenoid valve for a set time. The standard version offers 1–99 seconds per 100 Ah; other intervals are available on request. The actual dose depends on the pump capacity or valve flow rate.
Match the shunt and counter
The standard input accepts a 60 mV shunt signal or an equivalent rectifier signal. The display is calibrated for the shunt’s rated current and the required unit. Ah and Amin are available according to calibration; other quantities such as As or metal weight are available on request. The MB indicator monitors the measuring signal.
Technical overview
| Totaliser |
6-digit, electromechanical; key reset |
| Preset counter |
not fitted |
| Integrated dosing electronics |
DSZ timer with potential-free relay contact; 230 V / 10 A |
| Standard measuring input |
60 mV, calibrated to the shunt rating |
| Optional input |
10 V for total-current measurement via TMD U/U, on request |
| Measurement accuracy |
0.1% |
| Power supply |
230 V AC / 50–60 Hz |
| Ambient temperature |
0–50 °C |
| Shunt cable |
3 m |
Please specify the shunt rating and required counting unit when ordering. Check connections, output ratings and configuration for the actual version against the AZ2000DSZ operating instructions (PDF) and type plate. Contact us for selection advice.