The universal transmitter of the first generation with galvanic isolation for pH ORP and Conductivity.

In a DIN rail housing for control cabinet mounting.
The measuring range of the version for pH measurement is adjustable from 0...14 pH, 2...12 pH or 4...10 pH. This setting can be made by the user.
The version for Redox -ORP measurement measures from -1200...+1200 mV corresponding to 0(4)...20 mA.
The version for measuring electrical conductivity covers the range from 2 µS for a measuring cell with the cell constant of 0.01, to 20 mS for a conductivity measuring cell with the cell constant of 1.0.
All transmitters are available for 12 VDC or 24 VDC supply voltage.

pH - ORP - conductivity - Transmitter
With automatic temperature compensation.
The instrument converts the high-impedance input signal of the pH electrode into a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Order No. 0021.0410.1       24VDC     4...20mA     
Order No. 0021.0410.2       24VDC     0...20mA    
Order No. 0021.0410.3       12VDC     4...20mA   
Order No. 0021.0410.4       12VDC     0...20mA   
Order No. 0021.0410.5       24VDC     0...5V    
Order No. 0021.0410.6       24VDC     0...10V   
Order No. 0021.0410.7       12VDC     0...5V    
Order No. 0021.0410.8       12VDC     0...10V
Calibration setting on the device
198,00 EUR
plus 19% tax
pH-MVV PM2000
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH electrode pH62
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
ISO- Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
The instrument converts the input signal of the ORP electrode into a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Measuring range: -1200...+1200mV

Order No. 0021.0510.1       24VDC     4...20mA     
Order No. 0021.0510.2       24VDC     0...20mA    
Order No. 0021.0510.3       12VDC     4...20mA   
Order No. 0021.0510.4       12VDC     0...20mA   
Order No. 0021.0510.5       24VDC     0...5V    
Order No. 0021.0510.6       24VDC     0...10V   
Order No. 0021.0510.7       12VDC     0...5V    
Order No. 0021.0510.8       12VDC     0...10V
Calibration setting on the device
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
With automatic temperature compensation. The instrument converts the conductivity of the measured solution into a low- impedance output signal of 0(4)..20mA or 0..10V.
Measuring range: 0.001 µS...1000 mS
at ZK = 0.01 / 0.1 / 1
16 measuring ranges with LMN LF measuring cells
Output: 4...20 mA  /  0...20 mA  /  0...10 V
Supply voltage: 24 VDC


CC means cell constant

The specified measuring ranges refer to CC1 and are 
internal after opening the device by 3x jumper switchable.
The adjustment was carried out with 5m cable 4 x 0.34mm².
The data refer to µS/ mS/cm.
198,00 EUR
plus 19% tax
pH - ORP - conductivity - Transmitter
NEW
With automatic temperature compensation. The instrument converts the conductivity of the measured solution into a low- impedance output signal of 0(4)..20mA or 0..10V.
Measuring range: 0.001 µS...1000 mS
at ZK = 0.01 / 0.1 / 1
16 measuring ranges with LMN LF measuring cells
Output: 4...20 mA  /  0...20 mA  /  0...10 V
Supply voltage: 12 VDC


CC means cell constant

The specified measuring ranges refer to CC1 and are 
internal after opening the device by 3x jumper switchable.
The adjustment was carried out with 5m cable 4 x 0.34mm².
The data refer to µS/ mS/cm.