AZ2000: Totaliser
The AZ2000 measures the electric charge passed through an electroplating process. A six-digit electromechanical totaliser displays the accumulated value and can be reset with a key.
Pulses for an external dosing controller
An optocoupler output sends counting pulses to a suitable external pump controller. That controller converts the pulses into dosing strokes. This version does not include an integrated DSZ dosing timer.
Match the shunt and counter
The standard input accepts a 60 mV shunt signal or an equivalent rectifier signal. The display is calibrated for the shunt’s rated current and the required unit. Ah and Amin are available according to calibration; other quantities such as As or metal weight are available on request. The MB indicator monitors the measuring signal.
Technical overview
| Totaliser |
6-digit, electromechanical; key reset |
| Preset counter |
not fitted |
| Integrated dosing electronics |
not fitted; pulse output for external control |
| Standard measuring input |
60 mV, calibrated to the shunt rating |
| Optional input |
10 V for total-current measurement via TMD U/U, on request |
| Measurement accuracy |
0.1% |
| Power supply |
230 V AC / 50–60 Hz |
| Ambient temperature |
0–50 °C |
| Shunt cable |
3 m |
Please specify the shunt rating and required counting unit when ordering. Check connections, output ratings and configuration for the actual version against the AZ2000 operating instructions (PDF) and type plate. Contact us for selection advice.