pH-meters, Conductivity meters

Measuring and control instruments for pH, ORP, and conductivity.
To our interested parties and customers: 
Is there interest in devices with integrated data logger and network connection and MOD-Bus output?
0021.0510.3 -  ISO transducer for ORP voltage -1200...+1200mV  -  12VDC  -  4...20mA output
198,00 EUR
 
plus 19% tax
0022.7426  E.c. cell LMP-0.1-K-PVDF-3/4" W

E.c. cell LMP-0.1-K-PVDF-3/4" W

with Pt 100 for automatic temperature compensation
Cell constant: CC = 0.1
Material: PVDF, EPDM, 1.4571
Screw: 3/4"  
Version: short
with DIN 43650 connector
Recommended measuring range:-1000μS
162,00 EUR
 
plus 19% tax
0021.0510.4 -  ISO transducer for ORP voltage -1200...+1200mV  -  12VDC  -  0...20mA output
198,00 EUR
 
plus 19% tax
0022.1125  E.c. cell LM-0.1-K-PP-R

E.c. cell LM-0.1-K-PP-R
for immersion fitting TA32


Cell constant: CC = 0.1
Material: PP, EPDM, 1.4571
Version: short
for cable connector IP 67 (Art. 1510 000163)
Recommended measuring range:-500μS
91,00 EUR
 
plus 19% tax
0021.0510.5 -  ISO transducer for ORP voltage -1200...+1200mV  -  24VDC  -  0...5V output
198,00 EUR
 
plus 19% tax
0022.1225  E.c. cell LM-0.1-K-PVDF-R

E.c. cell LM-0.1-K-PVDF-R
for immersion fitting TA32


Cell constant: CC = 0.1
Material: PVDF, EPDM, 1.4571
Version: short
for cable connector IP 67 (Art. 1510 000163)
Recommended measuring range:-500μS
134,50 EUR
 
plus 19% tax
0021.0510.6 -  ISO transducer for ORP voltage -1200...+1200mV  -  24VDC  -  0...10V output
198,00 EUR
 
plus 19% tax
0022.1322  E.c. cell LMP-0.1-K-PP-R

E.c. cell LMP-0.1-K-PP-R
for immersion fitting TA32

with Pt 100 for automatic temperature compensation

Cell constant: CC = 0.1
Material: PP, EPDM, 1.4571
Version: short
for cable connector IP 67 (Art. 1510 000163)
Recommended measuring range:-1000μS
119,00 EUR
 
plus 19% tax
0021.0510.7 -  ISO transducer for ORP voltage -1200...+1200mV  -  12VDC  -  0...5V output
198,00 EUR
 
plus 19% tax
0022.1122  E.c. cell LMN-0.1-K-PP-R

E.c. cell LMN-0.1-K-PP-R
for immersion fitting TA32

with NTC 2K for automatic temperature compensation

Cell constant: CC = 0.1
Material: PP, EPDM, 1.4571
Version: short
for cable connector IP 67 (Art. 1510 000163)
Recommended measuring range:-500μS
114,00 EUR
 
plus 19% tax
0021.0510.8 -  ISO transducer for ORP voltage -1200...+1200mV  -  12VDC  -  0...10V output
198,00 EUR
 
plus 19% tax
0022.1422  E.c. cell LMP-0.1-K-PVDF-R

E.c. cell LMP-0.1-K-PVDF-R
for immersion fitting TA32

with Pt 100 for automatic temperature compensation

Cell constant: CC = 0.1
Material: PVDF, EPDM, 1.4571
Version: short
for cable connector IP 67 (Art. 1510 000163)
Recommended measuring range:-1000μS
162,00 EUR
 
plus 19% tax
0022.0410.1 -  ISO transducer for conductivity  -  24VDC  -  4...20mA output
ISO transducer for conductivity
in DIN rail case with automatic temperature compensation and
electrical isolation.
The instrument converts the conductivity of the measured solution
into a low- impedance output signal of 0(4)..20mA or 0..5/10V.
Measuring range: 0... 1S/cm with e.c. measuring cell LM, LMN
Output: 4... 20mA / 0... 20mA / 0... 5V/10V
Supply voltage: 12VDC  /  24VDC

CC means cell constant

The specified measuring ranges refer to CC1 and are 
internal after opening the device by 3x jumper switchable.
The adjustment was carried out with 5m cable 4 x 0.34mm².
The data refer to µS/ mS/ S/cm.

Order no. 0022.0410.1     24VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.2     24VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.3     12VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.4     12VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.5     24VDC   0... 5V          200µS/ 2mS/ 20mS
Order no. 0022.0410.6     24VDC   0... 10V        200µS/ 2mS/ 20mS
Order no. 0022.0410.7     12VDC   0... 5V          200µS/ 2mS/ 20mS 
Order no. 0022.0410.8     12VDC   0... 10V        200µS/ 2mS/ 20mS

For the following devices the measuring range is fixed to
200mS/cm for CC1, or 1S/cm for CC5.
Order no. 0022.0410.9     24VDC   4... 20mA    
Order no. 0022.0410.10   24VDC   0... 20mA   
Order no. 0022.0410.11   12VDC   4... 20mA   
Order no. 0022.0410.12   12VDC   0... 20mA   
Order no. 0022.0410.13   24VDC   0... 5V       
Order no. 0022.0410.14   24VDC   0... 10V     
Order no. 0022.0410.15   12VDC   0... 5V       
Order no. 0022.0410.16   12VDC   0... 10V    

Technische Daten Download PDF

198,00 EUR
 
plus 19% tax
0022.0410.2 -  ISO transducer for conductivity  -  24VDC  -  0...20mA output
198,00 EUR
 
plus 19% tax
0022.0410.3 -  ISO transducer for conductivity  -  12VDC  -   4...20mA output
198,00 EUR
 
plus 19% tax
0022.0410.4 -  ISO transducer for conductivity  -  12VDC  -   0...20mA output
198,00 EUR
 
plus 19% tax
0022.0410.5 -  ISO transducer for conductivity  -  24VDC  -   0...5V output
198,00 EUR
 
plus 19% tax
0022.0410.6 -  ISO transducer for conductivity  -  24VDC  -   0...10V output
198,00 EUR
 
plus 19% tax
0022.0410.7 -  ISO transducer for conductivity  -  12VDC  -   0...5V output
198,00 EUR
 
plus 19% tax
0022.0410.8 -  ISO transducer for conductivity  -  12VDC  -   0...10V output
198,00 EUR
 
plus 19% tax
Show 101 to 120 (from a total of 128 products)