pH - ORP - conductivity - Transmitter with galvanic isolation

Measuring transducer pH - ORP - conductivity with galvanic isolation

Technical Data pH-MT Download PDF
Technical Data ORP-MT Download PDF
Technical Data E.C.-MT Download PDF
pH - Redox - Conductivity - Transmitter with galvanic isolation with current or voltage output in DIN rail housing for control cabinet mounting.

Transducer for pH 2...12 / 0...14 - 24VDC - 4...20mA Output
With automatic temperature compensation.
The instrument converts the high-impedance input signal of the pH electrode into a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Order No. 0021.0410.1       24VDC     4...20mA     
Order No. 0021.0410.2       24VDC     0...20mA    
Order No. 0021.0410.3       12VDC     4...20mA   
Order No. 0021.0410.4       12VDC     0...20mA   
Order No. 0021.0410.5       24VDC     0...5V    
Order No. 0021.0410.6       24VDC     0...10V   
Order No. 0021.0410.7       12VDC     0...5V    
Order No. 0021.0410.8       12VDC     0...10V
Calibration setting on the device
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    24VDC    0...20mA Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    12VDC    4...20mA Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    12VDC    0...20mA Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    24VDC    0...5V Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    24VDC    0...10V Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    12VDC    0...5V Output
198,00 EUR
 
plus 19% tax
Transducer for pH 2...12 / 0...14    12VDC    0...10V Output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  24VDC  -  4...20mA output
The instrument converts the input signal of the ORP electrode into a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Measuring range: -1200...+1200mV

Order No. 0021.0510.1       24VDC     4...20mA     
Order No. 0021.0510.2       24VDC     0...20mA    
Order No. 0021.0510.3       12VDC     4...20mA   
Order No. 0021.0510.4       12VDC     0...20mA   
Order No. 0021.0510.5       24VDC     0...5V    
Order No. 0021.0510.6       24VDC     0...10V   
Order No. 0021.0510.7       12VDC     0...5V    
Order No. 0021.0510.8       12VDC     0...10V
Calibration setting on the device
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  24VDC  -  0...20mA output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  12VDC  -  4...20mA output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  12VDC  -  0...20mA output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  24VDC  -  0...5V output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  24VDC  -  0...10V output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  12VDC  -  0...5V output
198,00 EUR
 
plus 19% tax
Transducer for ORP voltage +-1200mV  -  12VDC  -  0...10V output
198,00 EUR
 
plus 19% tax
Transducer for conductivity  -  24VDC  -  4...20mA output
With automatic temperature compensation. The instrument converts the conductivity of the measured solution into a low- impedance output signal of 0(4)..20mA or 0..5/10V.
Measuring range: 0... 20 / 200 mS/cm with e.c. measuring cell LM, LMN
Output: 4... 20mA / 0... 20mA / 0... 5V/10V
Supply voltage: 12VDC  /  24VDC

CC means cell constant

The specified measuring ranges refer to CC1 and are 
internal after opening the device by 3x jumper switchable.
The adjustment was carried out with 5m cable 4 x 0.34mm².
The data refer to µS/ mS/cm.

Order no. 0022.0410.1     24VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.2     24VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.3     12VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.4     12VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.5     24VDC   0... 5V          200µS/ 2mS/ 20mS
Order no. 0022.0410.6     24VDC   0... 10V        200µS/ 2mS/ 20mS
Order no. 0022.0410.7     12VDC   0... 5V          200µS/ 2mS/ 20mS 
Order no. 0022.0410.8     12VDC   0... 10V        200µS/ 2mS/ 20mS

For the following devices the measuring range is fixed to
200mS/cm for CC1.

Order no. 0022.0410.9     24VDC   4... 20mA    
Order no. 0022.0410.10   24VDC   0... 20mA   
Order no. 0022.0410.11   12VDC   4... 20mA   
Order no. 0022.0410.12   12VDC   0... 20mA   
Order no. 0022.0410.13   24VDC   0... 5V       
Order no. 0022.0410.14   24VDC   0... 10V     
Order no. 0022.0410.15   12VDC   0... 5V       
Order no. 0022.0410.16   12VDC   0... 10V
198,00 EUR
 
plus 19% tax
Transducer for conductivity  -  24VDC  -  0...20mA output
198,00 EUR
 
plus 19% tax
Transducer for conductivity  -  12VDC  -   4...20mA output
198,00 EUR
 
plus 19% tax
Transducer for conductivity  -  12VDC  -   0...20mA output
198,00 EUR
 
plus 19% tax
Show 1 to 20 (from a total of 32 products)