ISO-transducers

Is also known as: iso transmitter, Transformer, galvanically isolated, galvanic isolation,

ISO - measuring - transducer for the measurement of pH / ORP, and the electrical conductivity.

ISO-transducers
0021.0410....  ISO transducer for pH 2...12 / 0...14
ISO measuring transducer for measuring range pH 2... 12 or 0... 14 
(adjustable by adjusting the slope)

in DIN rail case with automatic temperature compensation and electrical isolation.
The instrument converts the high-impedance input signal of the pH 
electrode into a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Order No. 0021.0410.1       24VDC     4...20mA     
Order No. 0021.0410.2       24VDC     0...20mA    
Order No. 0021.0410.3       12VDC     4...20mA   
Order No. 0021.0410.4       12VDC     0...20mA   
Order No. 0021.0410.5       24VDC     0...5V    
Order No. 0021.0410.6       24VDC     0...10V   
Order No. 0021.0410.7       12VDC     0...5V    
Order No. 0021.0410.8       12VDC     0...10V    

Calibration setting on the device

Technical Data Download PDF
Shippingtime: ca. 3-4 days ca. 3-4 days
(abroad may vary)
Weight: 0,08 kg per piece
198,00 EUR
plus 19% tax
0021.0510....  ISO transducer for ORP -1200...+1200mV
ISO transducer for ORP
in DIN rail case with electrical isolation.
The instrument converts the input signal of the ORP electrode into
a low-impedance output signal of 0(4)..20mA or 0..5/10V.

Measuring range: -1200...+1200mV

Order No. 0021.0510.1       24VDC     4...20mA     
Order No. 0021.0510.2       24VDC     0...20mA    
Order No. 0021.0510.3       12VDC     4...20mA   
Order No. 0021.0510.4       12VDC     0...20mA   
Order No. 0021.0510.5       24VDC     0...5V    
Order No. 0021.0510.6       24VDC     0...10V   
Order No. 0021.0510.7       12VDC     0...5V    
Order No. 0021.0510.8       12VDC     0...10V
Calibration setting on the device

Technical Data Download PDF
Shippingtime: ca. 3-4 days ca. 3-4 days
(abroad may vary)
Weight: 0,08 kg per piece
198,00 EUR
plus 19% tax
0022.0410...  ISO transducer for conductivity / 4...20mA
ISO transducer for conductivity
in DIN rail case with automatic temperature compensation and
electrical isolation.
The instrument converts the conductivity of the measured solution
into a low- impedance output signal of 0(4)..20mA or 0..5/10V.
Measuring range: 0... 1S/cm with e.c. measuring cell LM, LMN
Output: 4... 20mA / 0... 20mA / 0... 5V/10V
Supply voltage: 12VDC  /  24VDC

CC means cell constant

The specified measuring ranges refer to CC1 and are 
internal after opening the device by 3x jumper switchable.
The adjustment was carried out with 5m cable 4 x 0.34mm².
The data refer to µS/ mS/ S/cm.

Order no. 0022.0410.1     24VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.2     24VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.3     12VDC   4... 20mA     200µS/ 2mS/ 20mS 
Order no. 0022.0410.4     12VDC   0... 20mA     200µS/ 2mS/ 20mS
Order no. 0022.0410.5     24VDC   0... 5V          200µS/ 2mS/ 20mS
Order no. 0022.0410.6     24VDC   0... 10V        200µS/ 2mS/ 20mS
Order no. 0022.0410.7     12VDC   0... 5V          200µS/ 2mS/ 20mS 
Order no. 0022.0410.8     12VDC   0... 10V        200µS/ 2mS/ 20mS

For the following devices the measuring range is fixed to
200mS/cm for CC1, or 1S/cm for CC5.
Order no. 0022.0410.9     24VDC   4... 20mA    
Order no. 0022.0410.10   24VDC   0... 20mA   
Order no. 0022.0410.11   12VDC   4... 20mA   
Order no. 0022.0410.12   12VDC   0... 20mA   
Order no. 0022.0410.13   24VDC   0... 5V       
Order no. 0022.0410.14   24VDC   0... 10V     
Order no. 0022.0410.15   12VDC   0... 5V       
Order no. 0022.0410.16   12VDC   0... 10V    

Technische Daten Download PDF

Shippingtime: ca. 3-4 days ca. 3-4 days
(abroad may vary)
Weight: 0,08 kg per piece
198,00 EUR
plus 19% tax
Show 1 to 3 (from a total of 3 products)